RTD Specifications

ElementPT-100, PT-200, PT-500, PT-1000
Configuration :Simplex (Two/ Three/ Four wire ) Duplex ( Four/ Six/ Eight wire ) Triplex on Request
Temperature Range-200′ C up to 400′ C -200′ C up to 600′ C
 Sheath OD2 mm, 3 mm, 4 mm, 4.7 mm, 5 mm, 6 mm, 8 mm, 10 mm Others on Request
 Sheath MaterialSS316 as standard (Other on Request)
 AccuracyDIN Class-B, Class-A (Other on Request)
 InsulationMgO flled, Mineral Compact MgO (MI)
Open EndEnclosure/ Extension Cable / Quick connect – disconnect plug and jack / Spring loaded ceramic terminal block
EnclosureDie Cast Aluminum/ SS304/ SS316, single or double entry with 3/4” ET(F) cable entry as standard, 1/2” NPT(F) for well or nipple
ProtectionWeatherproof to IP-65, IP-67 Flameproof to Gr. IIA, IIB Flameproof to IIC ATEX certified CE Marked
Process Connection1/4” to 3/4” BSP/NPT (M) Welded or Compression Fittings, Adjustable Flange, Triclover Connections, Nipple or Nipple-Union-Nipple Extension
Extension Cable InsulationPTFE/PTFE PTFE/PTFE/SS Braided PTFE/ PTFE/ Silicon PTFE/ PTFE/ Shield/ PTFE Fiber / Fiber/ SS Braided
Optional AccessoriesHead Mounted Temperature Transmitter Various Cable Glands Thermowell
RTDs
  • Enclosure
  • Cable Entry

  •  Process Connection

  • Sheath
  • Sheath Length Below Head
  • Sheath Length Below Thread
  • Sheath Diameter
Scroll to Top